Cuff leak tests: analysis of diagnostic accuracy in observational cohorts of patients with acute respiratory failure


Submitted: 30 October 2011
Accepted: 12 January 2012
Published: 30 January 2012
Abstract Views: 3620
PDF: 1768
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

  • Diana Guerra Department of Internal Medicine,Texas Tech University Health Sciences Center, Lubbock, TX, United States.
  • Zachary Mulkey Department of Internal Medicine,Texas Tech University Health Sciences Center, Lubbock, TX, United States.
  • Kenneth Nugent Department of Internal Medicine,Texas Tech University Health Sciences Center, Lubbock, TX, United States.
Cuff leak tests provide clinicians with information about upper airway narrowing and may help predict weaning success. However, most clinical trials reporting this measurement are small, and the utility of this test remains uncertain. We identified all clinical studies using cuff leak tests in the PubMed, Google Scholar, EMBASE, and Cochrane Central Register of Controlled Trials databases using multiple search terms, including cuff leak test, laryngeal edema, extubation, and stridor, and abstracted quantitative information on cuff leaks and outcomes (stridor and reintubation). We reviewed six studies which included 958 patients with acute respiratory failure in intensive care units. Eighty-two patients (8.5%) had postextubation stridor. The weighted mean cuff leak was 119 (±51) mls in the patients with stridor and 313 (±24) mls in patients without stridor (P<0.01). Sixty-six patients required reintubation. The presence of stridor had a sensitivity of 0.60 (95% CI 0.48-0.72), a specificity of 0.96 (95% CI 0.94-0.97), and a positive likelihood ratio of 13.4 (95% CI 6.9-25.7) for predicting reintubation. No single clinical parameter consistently predicted stridor. Patients with postextubation stridor have smaller cuff leak volumes than patients who do not have stridor and are more likely to require reintubation. Cuff leak measurements can improve decision making with extubation protocols.

Supporting Agencies

none

Guerra, D., Mulkey, Z., & Nugent, K. (2012). Cuff leak tests: analysis of diagnostic accuracy in observational cohorts of patients with acute respiratory failure. Chest Disease Reports, 2(1), e3. https://doi.org/10.4081/cdr.2.263

Downloads

Download data is not yet available.

Citations