https://doi.org/10.4081/ejtm.2025.13503
The role of Power Doppler in ultrasound-guided percutaneous procedures: the Jet sign
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Published: 19 August 2025
In recent decades, ultrasound-guided percutaneous infiltrative procedures have gained prominence in treating musculoskeletal disorders, providing enhanced accuracy over traditional "blind" techniques. This study examines the utility of the Power Doppler ultrasound technique, specifically the "Jet sign," in identifying needle placement during infiltrative treatments. A retrospective analysis was conducted involving 5,376 patients where procedures were performed under ultrasound guidance from January 2014 to January 2022. While the needle tip was successfully visualized in 7% of cases, the Jet sign facilitated accurate localization in 368 instances. This technique capitalizes on the creation of a high-pressure fluid flow, enabling real-time monitoring and precise targeting of the therapeutic agent while minimizing complications. The findings underscore the effectiveness of the Jet sign in enhancing procedural accuracy and suggest its incorporation into clinical practice to optimize outcomes in ultrasound-assisted infiltrative therapies.
Downloads
Kianmehr N, Hasanzadeh A, Naderi F, et al. A randomized blinded comparative study of clinical response to surface anatomy guided injection versus sonography guided injection of hyaloronic acid in patients with primary knee osteoarthritis. Int J Rheum Dis 2018;21:134–9 DOI: https://doi.org/10.1111/1756-185X.13123
Cunnington J, Marshall N, Hide G, et al. A randomized, double-blind, controlled study of ultrasound-guided corticosteroid injection into the joint of patients with inflammatory arthritis. Arthritis Rheum 2010;62:1862-9. DOI: https://doi.org/10.1002/art.27448
Hashiuchi T, Sakurai G, Morimoto M, et al. Accuracy of the biceps tendon sheath injection: ultrasound-guided or unguided injection? A randomized controlled trial. J Shoulder Elbow Surg 2011;20:1069-73. DOI: https://doi.org/10.1016/j.jse.2011.04.004
Berkoff DJ, Miller LE, Block JE. Clinical utility of ultrasound guidance for intra-articular knee injections: a review. Clin Interv Aging 2012;7:89-95. DOI: https://doi.org/10.2147/CIA.S29265
Park KD, Kim TK, Lee J, et al. Palpation versus ultrasound-guided acromioclavicular joint intra-articular corticosteroid injections: a retrospective comparative clinical study. Pain Physician 2015;18:333-341. Correction in Pain Physician 2015;18:517. DOI: https://doi.org/10.36076/ppj.2015/18/333
Aly AR, Rajasekaran S, Ashworth N. Ultrasound‐guided shoulder girdle injections are more accurate and more effective than landmark‐ guided injections: a systematic review and meta‐analysis. Br J Sports Med 2015;49:1042‐9. DOI: https://doi.org/10.1136/bjsports-2014-093573
Koski JM. Ultrasound guided injections in rheumatology. J Rheumatol 2000;27:2131-8.
Bruyn GA, Schmidt WA. How to perform ultrasound-guided injections. Best Pract Res Clin Rheumatol 2009;23:269-79. DOI: https://doi.org/10.1016/j.berh.2008.11.001
Chin KJ, Perlas A, Chan VW, Brull R. Needle visualization in ultrasound-guided regional anesthesia: challenges and solutions. Reg Anesth Pain Med 2008;33:532-44. DOI: https://doi.org/10.1016/j.rapm.2008.06.002
Goldschmiedt J, Shilagani C, Patel H. The "injection jet sign": an innovative method of needle position confirmation during ultrasound guided injections. Skeletal Radiol 2017;46:559-63. DOI: https://doi.org/10.1007/s00256-017-2574-0
Epis O, Bruschi E. Interventional ultrasound: a critical overview on ultrasound-guided injections and biopsies. Clin Exp Rheumatol 2014;32:S78-S84.
Sánchez Barrancos IM, Manso García S, Lozano Gago P, et al. Utilidad y fiabilidad de la ecografía clínica musculoesquelética en medicina familiar (2): lesiones musculares, artrosis, enfermedades reumatológicas y procedimientos ecoguiados [Usefulness and reliabitlity of musculoskeletal point of care ultrasound in family practice (2): Muscle injuries, osteoarthritis, rheumatological diseases and eco-guided procedures]. Aten Primaria 2019;51:105-17. DOI: https://doi.org/10.1016/j.aprim.2018.07.011
Choo WS, Steeds RP. Cardiac imaging in valvular heart disease. Br J Radiol. 2011;84 Spec No 3(Spec Iss 3):S245-S257. DOI: https://doi.org/10.1259/bjr/54030257
Steeds RP. Echocardiography: frontier imaging in cardiology. Br J Radiol 2011;84:S237-45. DOI: https://doi.org/10.1259/bjr/77730594
Dubbins PA, Kurtz AB, Darby J, Goldberg BB. Ureteric jet effect: the echographic appearance of urine entering the bladder. A means of identifying the bladder trigone and assessing ureteral function. Radiology 1981;140:513-5. DOI: https://doi.org/10.1148/radiology.140.2.7255730
Cox IH, Erickson SJ, Foley WD, Dewire DM. Ureteric jets: evaluation of normal flow dynamics with color Doppler sonography. AJR Am J Roentgenol 1992;158:1051-5. DOI: https://doi.org/10.2214/ajr.158.5.1566665
Kremer H, Dobrinski W, Mikyska M, et al. Ultrasonic in vivo and in vitro studies on the nature of the ureteral jet phenomenon. Radiology 1982;142:175-7. DOI: https://doi.org/10.1148/radiology.142.1.7053530
Routh JC. Commentary on "Evaluation of ureteral jet dynamics in pediatric kidney stone formers: A cross-sectional study". J Pediatr Urol 2016;12:382. DOI: https://doi.org/10.1016/j.jpurol.2016.07.010
Scaturro D, Rizzo S, Sanfilippo V, et al. Effectiveness of rehabilitative intervention on pain, postural balance, and quality of life in women with multiple vertebral fragility fractures: a prospective cohort study. J Funct Morphol Kinesiol 2021;6:24. DOI: https://doi.org/10.3390/jfmk6010024
Bonaventura RE, Giustino V, Chiaramonte G, et al. Investigating prismatic adaptation effects in handgrip strength and in plantar pressure in healthy subjects. Gait Posture 2020;76:264-9. DOI: https://doi.org/10.1016/j.gaitpost.2019.12.022
Battaglia G, Messina G, Giustino V, et al. Influence of vertical dimension of occlusion on peak force during handgrip tests in athletes. Asian J Sports Med 2018;9:e68274. DOI: https://doi.org/10.5812/asjsm.68274
Thomas E, Bianco A, Raia T, et al. Relationship between velocity and muscular endurance of the upper body. Hum Mov Sci 2018;60:175-82. DOI: https://doi.org/10.1016/j.humov.2018.06.008
How to Cite

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
PAGEPress has chosen to apply the Creative Commons Attribution NonCommercial 4.0 International License (CC BY-NC 4.0) to all manuscripts to be published.