Determinazione quantitativa di HCV-RNA: valutazione comparativa dei saggi Abbott Real-Time e Versant bDNA v.3


Submitted: 18 February 2014
Accepted: 18 February 2014
Published: 30 June 2007
Abstract Views: 1083
PDF: 813
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

Hepatitis C virus (HCV) RNA measurement before, during and after antiviral therapy has become an essential tool in the management of interferon-based treatment of HCV-related infections. Conventional Polymerase Chain Reaction (PCR) has been largely used to obtain quantitative data, but laborious, time-consuming post-PCR handling steps are required to gain valuable results. Real time (RT) PCR now provides advantages over end-point (EP) PCR due to its improved rapidity, sensitivity, reproducibility and the reduced risk of carry-over contamination, and has now proven itself to be valuable for the more precise monitoring of viral load kinetics and assessing antiviral response.The Abbott Real-Time HCV-RNA is a recently introduced assay for the automated processing of clinical samples and HCV-RNA quantitation: its basic technology relies on use of fluorescent linear probes (dynamic range using 0.5 ml as input target= 12-108 IU/mL) and a hybridization/detection step at low temperature (35°C), which allows target mismatches to be tolerated. To determine the clinical application of the Abbott Real-Time assay and defining its correlation with the Bayer Versant bDNA v.3 assay, 68 consecutive samples from unselected HCV-infected patients were retrospectively analysed with RT and the results obtained using the two tests compared.A good correlation was found between RT-PCR and bDNA: 97% of samples tested had a result within a 0.5 log HCV IU/mL difference (bias=0.15 log), whereas 6 samples negative with bDNA gave positive results with Abbott RT (range, 1.89-3.07 log IU/mL) and “in-house” qualitative RT-PCR assays.

Manzin, A., Marinelli, K., Vecchi, M., Sestilli, P., & Pulvirenti, F. R. (2007). Determinazione quantitativa di HCV-RNA: valutazione comparativa dei saggi Abbott Real-Time e Versant bDNA v.3. Microbiologia Medica, 22(2). https://doi.org/10.4081/mm.2007.2619

Downloads

Download data is not yet available.

Citations