Axial penile rigidity influences patient and partner satisfaction after penile prosthesis implantation


Submitted: September 26, 2013
Accepted: September 26, 2013
Published: September 26, 2013
Abstract Views: 2500
PDF: 1950
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

Introduction: Penile prosthesis implantation is one of the treatment choices that is kept for patients who were not satisfied with other treatments. Although penile prosthesis satisfaction rates are higher, there are some dissatisfied patients. The patients’ reasons are mostly shortness and softness of implanted prosthesis. It was previously demonstrated that penile axial rigidity of more than 500 grams is enough for successful vaginal intromission. To our knowledge, there is no study comparing axial rigidity of penile prosthesis and satisfaction. Objectives: The aim of this study was to examine whether axial rigidity of penile prosthesis had impact on patient and partner satisfaction. Materials and Methods: We enrolled one hundred patients who were implanted penile prosthesis before to evaluate their penile axial rigidity. We used Rigidometry (by using the digital inflection rigidometer) to assess the minimal axial pressure to bend the implanted penis. Results: We demonstrated that mean axial pressure to bend the implanted penis was 984.8 ± 268.7 grams. Overall satisfaction score with the penile prosthesis implant was 4.55 and 4.49 (out of 5) in patients and partners, respectively. In total, seven men were unsatisfied with their implant and reported a mean satisfaction score of 0.6 ± 0.48 (out of 5). All prostheses types showed good and more than 500 grams axial rigidity. The patients with Ambicor type, which were buckled at about 710.5 grams, showed worse satisfaction rates in comparison to other prostheses in two patients. Digital inflection rigidometer results of other penile prosthesis types in unsatisfied patient were 842.0, 872.0, 887.0 and 920 g. in CX700, Titan, Genesis and Titan OTR, respectively. Conclusion: We demonstrated that dissatisfaction rate was highest in Ambicor prosthesis implanted patients. Additionally, patients with 3-piece penile prosthesis were more satisfied than 2-piece or malleable ones, interestingly, although some cases had lower axial rigidity results.

Al Ansari, A., Talib, R. A., Canguven, O., & Shamsodini, A. (2013). Axial penile rigidity influences patient and partner satisfaction after penile prosthesis implantation. Archivio Italiano Di Urologia E Andrologia, 85(3), 138–142. https://doi.org/10.4081/aiua.2013.3.138

Downloads

Download data is not yet available.

Citations